Short answer: Low water pressure in the house usually comes from a partly closed main valve, a failing pressure reducing valve (PRV), a hidden leak, clogged aerators or mineral-choked old pipes. First check whether the problem is one fixture or every faucet. One fixture usually means a clogged aerator or cartridge. The whole house points to the main valve, the PRV, a leak, old galvanized pipe or the supply from your utility or well.
Weak showers and slow-filling sinks are frustrating, and sometimes they are the first sign of a leak or worn-out pipes. The tests below narrow the cause in a few minutes. If the trouble is in the line from the street or the pipes inside your walls, PipeMend plumbers handle water line repair and replacement, and full repiping when old pipe is the problem.
Run cold water at several faucets, upstairs and down, and at an outdoor hose bib. Then compare hot and cold at the same faucet.
| What you notice | Most likely cause |
|---|---|
| One faucet or showerhead is weak | Clogged aerator, showerhead or cartridge |
| Only hot water is weak | Water heater valve, sediment or a scaled tankless unit |
| Every fixture is weak, suddenly | Main valve partly closed, PRV failure, utility problem or a big leak |
| Every fixture is weak, slowly worse over years | Scale inside galvanized pipe or a failing PRV |
| Weak only when two things run at once | Undersized pipes or service line |
| Weak or sputtering on a well | Pressure switch, pressure tank or well pump |
A screw-on pressure gauge from a hardware store fits an outdoor hose bib or a washing machine valve. Turn off all water in the house, attach the gauge, open the valve and read the static pressure. The City of Bloomington, Minnesota, lists 35 psi as adequate, 60 to 70 psi as optimal, and says a pressure regulating valve is needed at 80 psi. If your reading is low at the hose bib nearest the meter, the problem is upstream: the main valve, the PRV, the service line or the utility.
Possibly, if your home is older. The EPA warns that lead particles can attach to the surface of galvanized pipes and later enter the water. If you have galvanized pipe or an old service line, test your water and ask your utility what your service line is made of. Replacing old pipe fixes both the pressure and that risk.
Pressure that is too high is also a problem. It can make pipes bang (water hammer), cause toilets to run and make the water heater's relief valve drip. Bloomington's handout says a pressure regulating valve is required by code above 80 psi. If your gauge reads above 80, have a PRV installed or adjusted. Thermal expansion from a water heater in a closed system may also call for an expansion tank; see our guide to a leaking water heater.
If the shower is weak but the bathroom sink is fine, the problem is almost always in the shower itself. Start with the showerhead: unscrew it, soak it in vinegar and clear the holes with a toothpick. Many showerheads also have a small flow restrictor or screen at the inlet that clogs with grit. If a new showerhead doesn't help, the cartridge or mixing valve in the wall may be scaled or failing. A pressure-balancing valve can also cut flow if one side, usually the hot, is restricted. A plumber can replace the cartridge without opening the wall in most cases.
Pull-down kitchen faucets have a hose and a check valve inside the spray head, and both can trap debris. Take off the spray head and run the water into a bucket. If the flow is strong without the head, clean or replace the head. If it's still weak, check the two shutoff valves under the sink; they may be only partly open or failing inside. Old compression-style shutoffs are a common culprit and are cheap to replace.
When the water is shut off and turned back on, sediment and rust flakes can break loose and lodge in aerators, toilet fill valves and appliance inlet screens. If pressure dropped right after a repair or a utility main break, clean every aerator and check the inlet screens on the washing machine and dishwasher. Also confirm that whoever did the work fully reopened the main valve and any valves at the meter.
Homes on wells get their pressure from a pump and a pressure tank, not the city. A pressure switch turns the pump on at a low setting and off at a high one. Low or pulsing pressure can mean a failed pressure switch, a waterlogged pressure tank, a clogged sediment filter or a pump wearing out. Bloomington's handout lists 50 psi as typical for a well. A plumber or well contractor can test the tank's air charge and the switch settings.
Sometimes. A single clogged aerator is just maintenance. But pressure that drops suddenly across the whole house, along with a higher water bill, points to a leak that may be soaking a slab, a wall or the yard. Pressure that has faded slowly over years in an older home usually means the pipes themselves are near the end of their life. Brown or rusty water, banging pipes or a water heater relief valve that drips are other signs worth a plumber's visit. Catching these early keeps a small repair from becoming water damage.
Local note: Galvanized supply pipe is common in older homes in Ohio, Pennsylvania and Massachusetts, and it is a top cause of whole-house low pressure there. Very hard water in Utah and Nevada clogs aerators and valves quickly. Rural homes in Maine often trace low pressure to well pumps and pressure tanks.
Low water pressure in the house? Call 1-800-555-0199 and a PipeMend plumber can test and fix it.
Many utilities describe about 40 to 80 psi as normal, with 60 to 70 psi a comfortable target. The City of Bloomington, Minnesota, lists 60 to 70 psi as optimal and says a pressure regulating valve is needed at 80 psi.
Yes. A clogged softener or one sized too small can restrict flow. Bloomington's handout suggests opening the softener's bypass valve; if pressure improves, the softener is the cause.
Usually the problem is at the water heater: a partly closed valve, sediment in the tank or outlet, or a failing dip tube. A tankless unit with scale can also restrict hot water flow.
It can raise pressure when the supply from the street or a well is truly low. It won't fix clogged pipes or leaks, so find the cause first.
Yes. Pressure above 80 psi strains pipes, water heaters, toilets and appliances, and can make faucets bang and relief valves drip. A pressure reducing valve fixes it.

Pipes & Water Pressure
How to tell if you have polybutylene or galvanized pipe, why they fail, and how PEX and copper compare for a repipe.

Emergencies & Leaks
Where the main water shut-off valve usually is, how to close each valve type, and what to do if it won't turn.
Leak, clog or no hot water?
Call PipeMend 24/7 to get a licensed plumber started on the fix.
Call 1-800-555-0199